R325P Microstepping Driver

[vc_row][vc_column width=”2/3″][vc_custom_heading text=”R325P Microstepping Driver” font_container=”tag:h3|text_align:left|color:%2318489f” google_fonts=”font_family:Montserrat%3Aregular%2C700|font_style:400%20regular%3A400%3Anormal”][vc_column_text css_animation=”left-to-right”]

R325P_Single_Axis_Microstepping_Driver

The R325 is the most accurate microstepping driver in the World, merging the needs of performance and low cost. Our engineers have scrupulously designed this 256 microstepping driver to meet the needs of customers today. The R325 can handle +12 to 48VDC input Voltage, and supplies phase currents of 0.25 to 3.0 Amps Peak. Selectable step resolutions from Full, 2x, 4x, 8x, 16x, 32x, 64x, 128x, and 256x microstepping are available. Three optically isolated inputs and one optically isolated control output can be used for step, direction, disable/enable, and fault detection, respectively.
Microstepping, run and holding currents, and a test mode can be changed via dip switches, yet programming and storing these parameters may be more practical during mass production. A unique feature of allowing users to choose between dip switches and RS485/USB communication enables easy implementation for first time and OEM users.

How is the R325 accurate? Let’s first look at what makes a Bipolar Microstepping Driver not accurate. Stepper motors have a natural tendency to want to move towards their full step ON position. This magnetic pull is called the detent torque of the motor, which causes a jerking motion as the motor nears these positions. In a bipolar stepper motor, one phase will have 100% current and the other phase will have 0% current (this is what we’ll call the zero crossing point). Phases A and B are 90° offset and both have a sinusoidal current waveforms.

rs325output

Figure 1.1

Drivers that output a perfect sinusoidal current waveform will not have perfect accuracy. Engineers in the Motion Control Industry have gone through trial and error, tweaking the current sine waves in order to alleviate of the “jerk” that the motor makes as it is forcefully pulled towards the zero crossing spots. However, altering the waveform can greatly affect other areas of the driver’s performance.

Since these zero crossing spots are sensitive to the minimal amount of change, the R325 outputs the right amount of both holding and running current into the motor to overcome the motor’s detent torque. The following graphs use the same step motor to run the step-to-step tests. The R325 and a comparable driver were both set to 64 microstepping, the shaft of the motor was aligned to an encoder which graphed the position of the motor over time. Thus, a perfectly accurate step motor and driver combination would show a straight line, signifying an even amount of degrees in between each step.

closeupatzerocrossing

Figure 1.2 Compartive Driver

compartivedriver

Figure 1.3 Close up at the Zero Crossing

Figure 1.4 R325P Driver

Figure 1.5 Close up of the zero crossing. Spike is Elminated.




[/vc_column_text][/vc_column][vc_column width=”1/3″][vc_cta h2=”WHITE PAPERS” h2_font_container=”font_size:36|color:%23023178″ h2_use_theme_fonts=”yes” h4=”Read More White Papers” h4_font_container=”color:%237c7c7c|line_height:2″ h4_google_fonts=”font_family:Droid%20Sans%3Aregular%2C700|font_style:400%20regular%3A400%3Anormal” style=”outline” use_custom_fonts_h2=”true” use_custom_fonts_h4=”true” css=”.vc_custom_1447959600675{background-color: #f9f9f9 !important;}”]


Adhesives Enable Innovative Improvements in Stepper Motor Performance


Selecting a step motor for an application in the medical industry


Is Your Step Motor and Driver Contributing to the Inaccuracy of Your System?


R-Winding


Step Motor Accuracy


Step Motor Terminology got you stumped? Lin Engineering explains the differences between Amps/Phase and Amps Peak Current.


Step Motors in the Semi-Conductor Industry