[vc_row][vc_column width=”2/3″][vc_custom_heading text=”R-Winding” font_container=”tag:h3|text_align:left|color:%2318489f” google_fonts=”font_family:Montserrat%3Aregular%2C700|font_style:400%20regular%3A400%3Anormal”][vc_column_text css_animation=”left-to-right”]Most step motor users are familiar with Series and Parallel connections; now, the patented R-Winding (U.S. Patent No. 6,969,930) has been created to reduce noise and vibration for lower-torque applications.
Step motors typically run with a driver that either half steps or full steps. For example, a 1.8° stepper, one step will be 1.8° if set to full stepping or it will be 0.9° if it is set to half stepping. Looking closer at the electrical phase changes during half stepping, a typical sequence is to turn on, or give full current to, the A phase. Next, both A and B phases will be turned on, then A will turn off and only B will turn on, and so on. When only 1 phase is energized, we define this as the 1-Phase ON position. The chart below shows the sequencing process to make a motor turn.
[table id=90 /]
![]() |
| Figure 1. Traditional Step Response while half-stepping a 2-Phase Bipolar Step Motor |
If we were to depict the two Phases, A and B, in a vector diagram to demonstrate the relationship between the two electrical phases, the phase angles for each step is in increments of 45°: 0°, 45° 90°, 135°, 180°, 225°, 270°, 315° and back to 0°. At the 45° marker, this vector shows that both A and B phases are on because it is sitting in the first quadrant of the electrical phase diagram. When the vector shifts to 90°, it shows that the B phase is still on, and now A is off.
The settling time characteristics of the motor are different at 1-phase ON and 2-phase ON positions. The step time profile from every driver/controller assumes that the settling time character of each step is the same. Thus, erratic motion occurs when the step time is not synchronous with the rotor position. A traditional step response is shown in the figure 1 graph .
The R-winding was created to eliminate the 1-phase ON position and to minimize the differences in magnetic field over the entire range of the phase angles. With the new R-winding, the rotor position will be at 2-phase ON at all times during half-stepping. This can be made possible by not always applying 100% current into one phase only. Current is more evenly split between A and B phase. The new phase angles for each position will be 22.5°, 67.5°, 112.5°, 157.5°, 202.5°, 247.5°, 292.5°, 337.5° and back to 22.5. Thus, the settling time character of each step is now identical.
![]() |
| Electrical Phase Diagram |
If resonance or erratic motion occurs from step to step, corrective actions are to increase microstepping in order to decrease the oscillation of each step. But torque will decrease with microstepping. With the R-winding, users can eliminate resonance yet still remain the same output torque performance at half-stepping. Notice in the R-winding step response, each step is made with an even amount of step time profile.
![]() |
| New R-Winding Step Response |
[/vc_column_text][/vc_column][vc_column width=”1/3″][vc_cta h2=”WHITE PAPERS” h2_font_container=”font_size:36|color:%23023178″ h2_use_theme_fonts=”yes” h4=”Read More White Papers” h4_font_container=”color:%237c7c7c|line_height:2″ h4_google_fonts=”font_family:Droid%20Sans%3Aregular%2C700|font_style:400%20regular%3A400%3Anormal” style=”outline” use_custom_fonts_h2=”true” use_custom_fonts_h4=”true” css=”.vc_custom_1447959535155{background-color: #f9f9f9 !important;}”]
∗ Adhesives Enable Innovative Improvements in Stepper Motor Performance
∗ Selecting a step motor for an application in the medical industry
∗ Is Your Step Motor and Driver Contributing to the Inaccuracy of Your System?
∗ Step Motors in the Semi-Conductor Industry
[/vc_cta][/vc_column][/vc_row]